Technology
▪ Wall Insulation of Mineral wool 30cm
▪ Roof insulation of Polystyrene 35 cm
▪ Slab insulation of Polystyrene 20 cm
▪ YTONG NZEB light concrete
▪ Heating, ACC and Cooling with A/W Heat Pumps
▪ Ventilation type VAV with CO2 control and Heat Recovery and free cooling
▪ RES with PV and Thermal solar panels
▪ Monitoring and/or control with BMS for Room air temperatures and CO2 (ventilation), external temperature and CO2, Domestic hot water temperature in tanks
▪ Energy metres for Heating, Cooling, Ventilation, Domestic hot water, Lighting, PV, Thermal solar
Local Municipality
Construction: Under construction
Major renovation: N/A
Construction | U-value |
---|---|
Walls | |
Roof | |
Base |
Primary energy consumption (includes RES): 77kWh/mp/year
Building tightness: 1 ACH@50Pa
CO2 emissions: 9 kgCO2/mp/year
Renewable share of energy: 60%
Energy consumption and RES based on dynamic simulations (estimated)