Technology
Exterior wall
EvoHouse Wall Buildup:
- 13mm – Gypsum Board
- 38mm – Technical space
- 60mm – Cross Laminated Timber Wall
- 320mm – Steico Flex wood fibre insulation
- 60mm – Steico Protect wood fiberboard insulation
- 7mm – Nanopor white render
- U-value = 0.094 W/(m2K)
Basement floor / floor slab
EvoHouse Basement floor buildup:
- 12mm – Ceramics
- 80mm – Screed
- 30mm – XPS Polystyrene
- 100mm – XPS Polystyrene
- 150mm – Reinforced concrete slab – warm
- 200mm – XPS – 30 high resistance polystyrene
- 4mm – hydroinsulation
- 100mm – Reinforced concrete slab – cold
- U-value = 0.108 W/(m2K)
Roof
EvoHouse Roof buildup:
- 13mm – Gypsum board
- 100mm – Technical space
- 80mm – Cross Laminated Timber Slab
- 600mm – Steico Flex wood fibre insulation
- 15mm – OSB board
- Ventilated Attic under 2% Slope wooden roof structure
- U-value = 0.062 W/(m2K)
Frame
Internorm, KF 410 Thermo Passiv
- PVC-U
- Uf: 0.79
- U w-value = 0.84 W/(m2K)
Glazing
Internorm Solar+ 0,6 Argon – 48 mm (Edition passiv)
- U g-value = 0.62 W/(m2K)
- g -value = 60 %
Entrance door
Internorm Door
- U d-value = 0.79 W/(m2K)
Ventilation
Zehnder, ComfoAir 200 92% Heat recovery efficiency with Enthalpy exchanger
Heating installation
Panasonic Aquarea 9kW Bi-Bloc Air-to-water heat pump with 4.5 COP value with buffer and bathroom comfort radiators. (500W/bathroom)
Domestic hot water
Panasonic Aquarea 9kW Bi-Bloc Air-to-water heat pump with 4.5 COP value. 1000 litre storage.
Ecological aspects
100% ecologic superstructure: Cross Laminated Timber structure and 100% recycled wood fibre insulation, wooden roof.
Private owners
Construction: 2014
Major Renovation: N/A
Construction | U-value |
---|---|
Walls | |
External Wall |
0.094 W/m²K |
Roof | |
Base | |
Basement floor / floor slab |
0.108 W/m²K |
Windows | Uw | Uf | Ug | G |
---|---|---|---|---|
Windows |
0.84 W/m²K | 0.79 W/m²K | 0.62 W/m²K | 60 % |
Doors | U-value |
---|---|
Entrance Door |
0.79 W/m²K |
Primary energy consumption: 96 kWh/m2year
Building tightness: 0.28/h
CO2 emissions: 11 kgCO2/m2year
Renewable share of energy: 50%